Sidestream dark field imaging of the serosal microcirculation during gastrointestinal surgery

A. F. J. de Bruin*, V. N.N. Kornmann, K. van der Sloot, J. L. van Vugt, M. P. Gosselink, A. Smits, B. Van Ramshorst, E. C. Boerma, P. G. Noordzij, D. Boerma, M. van Iterson

*Corresponding author for this work

Research output: Contribution to journalArticleAcademicpeer-review

35 Citations (Scopus)

Abstract

Aim: The study aimed to describe the serosal microcirculation of the human bowel using sidestream dark field imaging, a microscopic technique using polarized light to visualize erythrocytes through capillaries. We also compared its feasibility to the current practice of sublingual microcirculatory assessment. Method: In 17 patients sidestream dark field measurements were performed during gastrointestinal surgery. Microcirculatory parameters like microvascular flow index (MFI), proportion of perfused vessels (PPV), perfused vessel density (PVD) and total vessel density (TVD) were determined for every patient, sublingually and on the bowel serosa. Results: Sixty measurements were done on the bowel of which eight (13%) were excluded, five owing to too much bowel peristalsis and three because of pressure artefacts. Image stability was in favour of sublingual measurements [pixel loss per image, bowel 145 (95% CI 126-164) vs sublingual 55 (95% CI 41-68); P < 0.001] and time to acquire a stable image [bowel 96 s (95% CI 63-129) vs sublingual 46 s (95% CI 29-64); P = 0.013]. No difference in the MFI was observed [bowel 2.9 (interquartile range 2.87-2.95) vs sublingual 3.0 (interquartile range 2.91-3.0); P = 0.081]. There was a difference in the PPV [bowel 95% (95% CI 94-96) vs sublingual 97% (95% CI 97-99); P < 0.001], PVD [bowel 12.9 mm/mm2 (95% CI 11.1-14.8) vs sublingual 17.4 mm/mm2 (95% CI 15.6-19.1); P = 0.003] and the TVD [bowel 13.6 mm/mm2 (95% CI 11.6-15.6) vs sublingual 17.7 mm/mm2 (95% CI 16.0-19.4); P = 0.008]. Conclusion: Sidestream dark field imaging is a very promising technique for bowel microcirculatory visualization and assessment. It is comparable to sublingual assessment and the analysis produces a similar outcome with slightly differing anatomical features.

Original languageEnglish
Pages (from-to)O103-O110
JournalColorectal Disease
Volume18
Issue number3
DOIs
Publication statusPublished - 1-Mar-2016
Externally publishedYes

Keywords

  • Bowel perfusion
  • Bowel serosal microcirculation
  • Microcirculation
  • Sidestream dark field imaging

Fingerprint

Dive into the research topics of 'Sidestream dark field imaging of the serosal microcirculation during gastrointestinal surgery'. Together they form a unique fingerprint.

Cite this